How to import a session file and regenerate scripts?
Rational Robot FAQ
(Continued from previous question...)
How to import a session file and regenerate scripts?
You can import a session from a different computer into your current project.
- In Robot, click Tools > Import Session. The Open dialog box appears.
- Click the session file, then click Open. The session and its scripts are now in
your project.
- To regenerate the scripts in the session you imported, click Tools > Regenerate
Test Scripts from Session, and select the session you imported.
- To regenerate the suite, click Tools > Rational Suite TestStudio > Rational
TestManager.
- Click File > New Suite. The New Suite dialog box appears.
- Select Existing Session, and click OK.
- TestManager displays a list of sessions that are in the project. Click the name of
the session that you imported, and click OK.
(Continued on next question...)