background image
<< Applying Sequence Diagram Filters | Editing Trigger or Filter Events >>
<< Applying Sequence Diagram Filters | Editing Trigger or Filter Events >>

Start and End of Runtime Tracing

Test RealTime - User Guide
To import one or several filters:
1. Click
the
Import button.
2.
Locate and select the .tft file(s) that you want to import.
3. Click
OK.
To export a filter event:
1.
Select the filter that you want to export.
2. Click
the
Export button.
3.
Select the location and name of the exported .tft file.
4. Click
OK.
Using Sequence Diagram Triggers
Sequence Diagram triggers allow you to predefine automatic start and stop
parameters for the UML/SD Viewer. The trigger capability is useful if you only want
to trace a specific portion of an instrumented application.
Triggers can be inactive, time-dependent, or event-dependent.
To access the Trigger dialog box:
1. From
the
UML/SD Viewer menu, select Triggers or click the Trigger button in
the UML/SD Viewer toolbar.
Start and End of Runtime Tracing:
The Runtime Tracing start is defined on the Start tab:
·
At the beginning: Runtime Tracing starts when the application starts.
·
On time: Runtime Tracing starts after a specified number of microseconds.
·
On event: Runtime Tracing starts when a specified event is detected. One or
several events must be specified with the Event Editor.
The Runtime Tracing end is defined on the Stop tab:
·
Never: Runtime Tracing ends when the application exits.
·
On time: Runtime Tracing ends after a specified number of seconds.
·
On event: Runtime Tracing ends when a specified event is detected. One or
several events must be specified with the Event Editor.
To create a new trigger event:
1. Click
the
New button
260